Pipe ID Control System

Measurement principle - laser rescanning by rotational triangulation sensor.

Get PricingInquires
Models
  • RF096-35/55-100

    RF096-35/55-100

    Measured ID range, mm: 35...55
    ID measurement accuracy, mm: ±0.05
    Angle scan resolution, points for turnover: 3200
    See detailed specifications →
Specifications

Pipe ID Control System

Parameter Value
Measured ID range, mm 35...55
ID measurement accuracy, mm ±0,05
Linear translation accuracy, mm ±0,05
Pipe depth, mm 100
Angle scan resolution, points for turnover 3200
Laser sensor linearity, μm ±15
Laser sensor resolution, μm 3
Laser sensor sample frequency, Hz 9400
Laser sensor output power, mW <1
Laser safety class 2  (IEC60825-1)
Light source red semiconductor laser, 660 nm wavelength
Interface Ethernet and PROFINET
Power supply, V 220
Measurement time, s <5
Environmental resistance:
  Vibration 20 g / 10...1000 Hz, 6 hours for each of XYZ axes
Shock 30 g / 6 ms
Permissible ambient light, lx 30000
Relative humidity, % 5-95% (no condensation)
Operating ambient temperature,, °С 0…+45
Storage temperature,, °С -20…+70
Weight (without cables), gram 6800
Operation

Operation of the system is based on scanning the pipe inner surface with a rotating triangulation laser sensor.

The system contains a base on which the linear translation mechanism, the controller and the interface module are installed. The linear translation mechanism carries the rotation module on which the laser sensor is mounted. On the back of the system there are four connectors for power and interfaces.

 


RF096-35/55-100
Figure 1. System structure

The system operates as follows.

The measured pipe is installed coaxially with the laser sensor. At the command of an external controller, the laser sensor moves into the hole. The sensor begins to rotate and scans the inner surface of the pipe, transmits the polar coordinates of the surface (distance from the axis of rotation measured by the sensor and the corresponding angle of rotation) to the built-in computer to calculate the required geometric parameters. The result is transmitted to the external controller via PROFINET.

Video

Pipe ID Control System

Order info

Order information for Pipe ID Control System

RF096-Dmin/Dmax-L

Symbol Description
Dmin/Dmax ID measurement range, mm.
L Measurement depth, mm.

Example: RF096-35/55-100 - Steel Pipe ID Control System, ID measurement range - 35...55 mm, measurement depth - 100 mm.

Search

 

Site sections

More links

© 2001 – 2019 RIFTEK LLC

Logoisky tract, 22, Minsk, Republic of Belarus

Tel/fax:  +375 (17) 357-36-57

Mobile:   +375 (29) 655-72-55

E-mail: info@riftek.com

Our partners in other countries

  • Country*:
  • Name*:
  • Company*:
  • E-mail*:
  • Confirm your e-mail*:
  • Phone number:
  • Message*:

* - Required

Send